Disposable Hot Biopsy Forceps
Using insulated monopolar electrocoagulating forceps, Disposable Hot Biopsy Forceps technique simultaneously electrocoagulates and biopsies tissue.
High frequency current is used to hot biopsy forceps to remove tiny polyps (up to a size of 5 mm) from the upper and lower gastrointestinal system.

Features
Rich design of forceps cups meets various needs of doctors.
The head of the biopsy forceps can be opened and closed easily and flexibly, and the incision is sharp. Used with high frequency generator, it has the function of coagulation and electric cutting.
The outer surface is coated with a special material super-smooth coating, which can be inserted smoothly into the forceps channel, effectively reducing the wear of the instruments on the endoscope forceps channel.
Small wound surface, no tissue charring, fast healing.
Unique four-bar plier head design, the jaws are firmly engaged and not easy to slip off.
Temperature controllable, suitable for a variety of cuts, fast coagulation, short operation time.
Sterile packaging, easy to use.
Table 1-Models of Disposable Hot Biopsy Forceps
|
Model |
Specifìcation |
Jaw Diamete D (mm) |
Effective Shaft Length L (mm) |
Working Channel |
|
A |
HF18-24/60 |
2.40-0.2 |
600±100 |
¢2.8 |
|
HF18-24/120 |
2.40-0.2 |
1200±100 |
¢2.8 |
|
|
HF18-24/160 |
2.40-0.2 |
1600±100 |
¢2.8 |
|
|
HF18-24/180 |
2.40-0.2 |
1800±100 |
¢2.8 |
|
|
HF18-24/200 |
2.40-0.2 |
2000±100 |
¢2.8 |
|
|
HF18-24/230 |
2.40-0.2 |
2300±100 |
¢2.8 |
|
|
B |
HF18-18/60 |
1.80-0.2 |
600±100 |
¢2.0 |
|
HF18-18/120 |
1.80-0.2 |
1200±100 |
¢2.0 |
|
|
HF18-18/160 |
1.80-0.2 |
1600±100 |
¢2.0 |
|
|
HF18-18/180 |
1.80-0.2 |
1800±100 |
¢2.0 |
|
|
HF18-18/200 |
1.80-0.2 |
2000±100 |
¢2.0 |
Functional Characteristics
The opening and closing of the clamp head is easy and flexible, and there is no plugging phenomenon. It has the function of electrocoagulation and electric cutting when used with high frequency generator.
Packaging
One device per pouch, ten pouches per cartonten cartons per outer box.
Contraindication
1. Patients with poor general condition, who can not tolerate the endoscopy.
2. Patients with upper digestive tract is narrow, the endoscope is unable to pass through.
3. Patients with severe coagulation dysfunction and hemorrhagic disease.
4. Patients with upper digestive tract acute inflammation, ulcers.
5. The patient is allergic to the product and the medicine used in the operation.
6. Patients with high frequency interference devices, such as cardiac pacemaker.
7. Patients are not suitable for the use of this product.
Product Sterilization Information
The device is sterilized by EO. Do not re-sterilize
Validity
3 years.